{"id":1469,"date":"2025-10-24T17:22:08","date_gmt":"2025-10-24T17:22:08","guid":{"rendered":"https:\/\/smart-energy-engineering.ch\/?page_id=1469"},"modified":"2026-10-18T13:17:37","modified_gmt":"2026-10-18T13:17:37","slug":"unterstuetzte-geraete","status":"publish","type":"page","link":"https:\/\/smart-energy-engineering.ch\/?page_id=1469","title":{"rendered":"Unterst\u00fctzte Ger\u00e4te"},"content":{"rendered":"\n<p>Der <strong>Eigenverbrauchsmanager<\/strong> unterst\u00fctzt aktuell folgende Ger\u00e4te<\/p>\n\n\n\n<p><strong>ABB Stromz\u00e4hler (mit MID Zulassung)<\/strong><br>&#8211; Baureihe B23\/24 Dreiphasen Ein-\/Zweirichtungsz\u00e4hler Modbus RTU oder M-Bus*, direktmessend oder Wandler<br>*f\u00fcr die M-Bus-Variante ist ein M-Bus-TCP-Konverter notwendig<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"281\" height=\"309\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image.png\" alt=\"\" class=\"wp-image-1470\" style=\"width:211px;height:232px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image.png 281w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-273x300.png 273w\" sizes=\"auto, (max-width: 281px) 100vw, 281px\" \/><\/figure>\n\n\n\n<p><strong>Eltako Stromz\u00e4hler (mit MID Zulassung)<\/strong><br>&#8211; Baureihe DSZ14-(W)DRS Dreiphasen-Einrichtungsz\u00e4hler, direktmessend oder Wandler<br>Es wird ein Eltako FAM14-Koppler und FBA14 ben\u00f6tigt.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"252\" height=\"252\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-1.png\" alt=\"\" class=\"wp-image-1472\" style=\"width:189px;height:189px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-1.png 252w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-1-150x150.png 150w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-1-100x100.png 100w\" sizes=\"auto, (max-width: 252px) 100vw, 252px\" \/><\/figure>\n\n\n\n<p><strong>Shelly Stromz\u00e4hler<\/strong><br>&#8211; Shelly 3EM Dreiphasen-Zweirichtungsz\u00e4hler WLAN \u00fcber Wandler<br>&#8211; Shelly 3EM Pro Dreiphasen-Zweirichtungsz\u00e4hler LAN \u00fcber Wandler<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"674\" height=\"444\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-2.png\" alt=\"\" class=\"wp-image-1474\" style=\"width:337px;height:222px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-2.png 674w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-2-300x198.png 300w\" sizes=\"auto, (max-width: 674px) 100vw, 674px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"405\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-3.png\" alt=\"\" class=\"wp-image-1475\" style=\"width:240px;height:203px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-3.png 480w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-3-300x253.png 300w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><\/figure>\n\n\n\n<p><strong>Smart-me Z\u00e4hler<\/strong><br>&#8211; Telstar Dreiphasen-Zweirichtungsz\u00e4hler 3x80A WLAN<br>Diese Z\u00e4hler haben eine MID\/METAS-Zertifizierung f\u00fcr Abrechnungszwecke (ZEV).<br>Die Einbindung erfolgt \u00fcber die Smart-me-Cloud<\/p>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-1024x1024.png\" alt=\"\" class=\"wp-image-1476\" style=\"width:256px;height:256px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-1024x1024.png 1024w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-300x300.png 300w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-150x150.png 150w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-768x768.png 768w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-1536x1536.png 1536w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4-100x100.png 100w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-4.png 1800w\" sizes=\"auto, (max-width: 706px) 89vw, (max-width: 767px) 82vw, 740px\" \/><\/figure>\n\n\n\n<p><strong>WhatWatt Adapter<\/strong><br>Der Adapter unterst\u00fctzt alle g\u00e4ngigen Smart-Meter in der CH und kann die Daten in Echtzeit aus der Kundenschnittstelle lesen.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"339\" height=\"411\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-5.png\" alt=\"\" class=\"wp-image-1477\" style=\"width:170px;height:206px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-5.png 339w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-5-247x300.png 247w\" sizes=\"auto, (max-width: 339px) 100vw, 339px\" \/><\/figure>\n\n\n\n<p><strong>gPlug Adapter<\/strong><br>Diese Adapter unterst\u00fctzen alle g\u00e4ngigen Smart-Meter in der CH und k\u00f6nnen die Daten in Echtzeit aus der Kundenschnittstelle lesen. Je nach Schnittstelle ist ein anderer Adapter notwendig (es werden alle unterst\u00fctzt):<br>&#8211; gPlugM f\u00fcr M-Bus<br>&#8211; gPlugD f\u00fcr P1-DSMR<br>&#8211; gPlugK f\u00fcr Kamstrup<br>&#8211; gPlugD-E f\u00fcr P1-DSMR \u00fcber Ethernet<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"445\" height=\"426\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-6.png\" alt=\"\" class=\"wp-image-1478\" style=\"width:223px;height:213px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-6.png 445w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-6-300x287.png 300w\" sizes=\"auto, (max-width: 445px) 100vw, 445px\" \/><\/figure>\n\n\n\n<p><strong>Eltako Temperaturf\u00fchler<\/strong><br>&#8211; FTF65(S) Raumtemperaturf\u00fchler<br>Zur Messung der Raumtemperatur \u00fcber EnOcean-Funk.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"203\" height=\"198\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-8.png\" alt=\"\" class=\"wp-image-1481\" style=\"width:152px;height:149px\"\/><\/figure>\n\n\n\n<p><strong>Thermokon Temperaturf\u00fchler<\/strong><br>&#8211; Baureihe SR65 Funk-Speicher-\/Tauch-\/Aussenf\u00fchler<br>&#8211; Baureihe WRF04 Raumf\u00fchler Modbus RTU<br>&#8211; Baureihe NOVOS3 Raumf\u00fchler Modbus RTU<br>&#8211; Baureihe AKF10 Speicher-\/Tauchf\u00fchler Modbus RTU<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"144\" height=\"256\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-9.png\" alt=\"\" class=\"wp-image-1482\" style=\"width:72px;height:128px\"\/><figcaption class=\"wp-element-caption\">SR65 AKF<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"348\" height=\"237\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-11.png\" alt=\"\" class=\"wp-image-1484\" style=\"width:174px;height:119px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-11.png 348w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-11-300x204.png 300w\" sizes=\"auto, (max-width: 348px) 100vw, 348px\" \/><figcaption class=\"wp-element-caption\">SR65 TF<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"267\" height=\"194\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-12.png\" alt=\"\" class=\"wp-image-1485\" style=\"width:134px;height:97px\"\/><figcaption class=\"wp-element-caption\">SR65 ATF<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"302\" height=\"302\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-13.png\" alt=\"\" class=\"wp-image-1486\" style=\"width:76px;height:76px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-13.png 302w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-13-300x300.png 300w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-13-150x150.png 150w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-13-100x100.png 100w\" sizes=\"auto, (max-width: 302px) 100vw, 302px\" \/><figcaption class=\"wp-element-caption\">WRF04<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"381\" height=\"411\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-14.png\" alt=\"\" class=\"wp-image-1487\" style=\"width:95px;height:103px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-14.png 381w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-14-278x300.png 278w\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" \/><figcaption class=\"wp-element-caption\">NOVOS 3<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"373\" height=\"382\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-15.png\" alt=\"\" class=\"wp-image-1489\" style=\"width:93px;height:96px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-15.png 373w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-15-293x300.png 293w\" sizes=\"auto, (max-width: 373px) 100vw, 373px\" \/><figcaption class=\"wp-element-caption\">AKF10<\/figcaption><\/figure>\n\n\n\n<p><strong>Shelly Temperaturf\u00fchler<\/strong><br>&#8211; Shelly H&amp;T Temperatur- und Feuchtemessung WLAN ohne Anzeige<br>&#8211; Shelly H&amp;T Plus Temperatur- und Feuchtemessung WLAN mit Anzeige<br>&#8211; Add On Plus f\u00fcr 3x Pt100 WLAN (kann z.B. auf Relais 1PM aufgesteckt werden)<br>Die Einbindung erfolgt \u00fcber die Shelly Cloud. Es werden nur die Temperaturwerte ausgewertet.<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"275\" height=\"247\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-16.png\" alt=\"\" class=\"wp-image-1490\" style=\"width:138px;height:124px\"\/><figcaption class=\"wp-element-caption\">H&amp;T<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"288\" height=\"264\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-17.png\" alt=\"\" class=\"wp-image-1491\" style=\"width:144px;height:132px\"\/><figcaption class=\"wp-element-caption\">H&amp;T Plus<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"327\" height=\"277\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-19.png\" alt=\"\" class=\"wp-image-1493\" style=\"width:164px;height:139px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-19.png 327w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-19-300x254.png 300w\" sizes=\"auto, (max-width: 327px) 100vw, 327px\" \/><figcaption class=\"wp-element-caption\">Add-On Plus<\/figcaption><\/figure>\n\n\n\n<p><strong>Shelly Heizk\u00f6rperthermostat<\/strong><br>&#8211; Shelly TRV Thermostat WLAN mit Stellmotor<br>Die Einbindung erfolgt \u00fcber die Shelly-Cloud. Es werden nur Temperatur Ist- und Sollwert ausgelesen.<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"305\" height=\"350\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-18.png\" alt=\"\" class=\"wp-image-1492\" style=\"width:153px;height:175px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-18.png 305w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-18-261x300.png 261w\" sizes=\"auto, (max-width: 305px) 100vw, 305px\" \/><figcaption class=\"wp-element-caption\">TRV<\/figcaption><\/figure>\n\n\n\n<p><strong>W\u00e4rmez\u00e4hler<\/strong><br>\u00dcber M-Bus k\u00f6nnen diverse W\u00e4rmez\u00e4hler eingelesen werden. Folgende Typen werden aktuell unterst\u00fctzt:<br>&#8211; Techem Kamstrup Multical 302 \/ 403<br>&#8211; Zenner Zelsius C5-IUF, optional Heating&amp;Cooling (W\u00e4rme und K\u00e4lte)<br>&#8211; Neovac SuperCal 739<br>Die Z\u00e4hler sind MID zertifiziert f\u00fcr Abrechnungszwecke.<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"388\" height=\"374\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-20.png\" alt=\"\" class=\"wp-image-1495\" style=\"width:194px;height:187px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-20.png 388w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-20-300x289.png 300w\" sizes=\"auto, (max-width: 388px) 100vw, 388px\" \/><figcaption class=\"wp-element-caption\">Multical 403<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"403\" height=\"319\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-21.png\" alt=\"\" class=\"wp-image-1496\" style=\"width:202px;height:160px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-21.png 403w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-21-300x237.png 300w\" sizes=\"auto, (max-width: 403px) 100vw, 403px\" \/><figcaption class=\"wp-element-caption\">Multical 302<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"392\" height=\"503\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-22.png\" alt=\"\" class=\"wp-image-1497\" style=\"width:196px;height:252px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-22.png 392w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-22-234x300.png 234w\" sizes=\"auto, (max-width: 392px) 100vw, 392px\" \/><figcaption class=\"wp-element-caption\">Zelsius C5-IUF<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"386\" height=\"503\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-23.png\" alt=\"\" class=\"wp-image-1498\" style=\"width:193px;height:252px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-23.png 386w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-23-230x300.png 230w\" sizes=\"auto, (max-width: 386px) 100vw, 386px\" \/><figcaption class=\"wp-element-caption\">SuperCal 739<\/figcaption><\/figure>\n\n\n\n<p><strong>Wasserz\u00e4hler<\/strong><br>\u00dcber M-Bus k\u00f6nnen diverse Wasserz\u00e4hler eingelesen werden. Folgende Typen werden aktuell unterst\u00fctzt:<br>&#8211; Techem Q3 2.5T90<br>&#8211; NeoVac Picoflux Typ EF<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"381\" height=\"446\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-24.png\" alt=\"\" class=\"wp-image-1500\" style=\"width:191px;height:223px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-24.png 381w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-24-256x300.png 256w\" sizes=\"auto, (max-width: 381px) 100vw, 381px\" \/><figcaption class=\"wp-element-caption\">Techem Q3<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"389\" height=\"447\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-25.png\" alt=\"\" class=\"wp-image-1501\" style=\"width:195px;height:224px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-25.png 389w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-25-261x300.png 261w\" sizes=\"auto, (max-width: 389px) 100vw, 389px\" \/><figcaption class=\"wp-element-caption\">NeoVac Picoflux<\/figcaption><\/figure>\n\n\n\n<p><strong>Eltako Funk-Relais (EnOcean)<\/strong><br>&#8211; Baureihe FSR14* (2x und 4xRelais)<br>&#8211; Baureihe FSR61 (inkl. Messung Scheinleistung)<br>&#8211; Baureihe FSR71<br>*Einbindung \u00fcber den Funk-Koppler FAM14<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"191\" height=\"356\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-26.png\" alt=\"\" class=\"wp-image-1503\" style=\"width:96px;height:178px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-26.png 191w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-26-161x300.png 161w\" sizes=\"auto, (max-width: 191px) 100vw, 191px\" \/><figcaption class=\"wp-element-caption\">FSR14<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"320\" height=\"462\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-27.png\" alt=\"\" class=\"wp-image-1506\" style=\"width:160px;height:231px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-27.png 320w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-27-208x300.png 208w\" sizes=\"auto, (max-width: 320px) 100vw, 320px\" \/><figcaption class=\"wp-element-caption\">FAM14<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"485\" height=\"440\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-28.png\" alt=\"\" class=\"wp-image-1507\" style=\"width:121px;height:110px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-28.png 485w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-28-300x272.png 300w\" sizes=\"auto, (max-width: 485px) 100vw, 485px\" \/><figcaption class=\"wp-element-caption\">FSR61-VA<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"471\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-29.png\" alt=\"\" class=\"wp-image-1508\" style=\"width:107px;height:236px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-29.png 213w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-29-136x300.png 136w\" sizes=\"auto, (max-width: 213px) 100vw, 213px\" \/><figcaption class=\"wp-element-caption\">FSR71<\/figcaption><\/figure>\n\n\n\n<p><strong>MyStrom Switch<\/strong><br>&#8211; MyStrom WiFi Switch (Einbindung \u00fcber WLAN)<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"358\" height=\"438\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-30.png\" alt=\"\" class=\"wp-image-1510\" style=\"width:179px;height:219px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-30.png 358w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-30-245x300.png 245w\" sizes=\"auto, (max-width: 358px) 100vw, 358px\" \/><figcaption class=\"wp-element-caption\">MyStrom Switch<\/figcaption><\/figure>\n\n\n\n<p><strong>Shelly Relais<\/strong><br>&#8211; Baureihen Shelly 1PM, 2PM und 4PM Pro \u00fcber WLAN (oder LAN)<br>&#8211; Shelly Plug S \u00fcber WLAN (Zwischenstecker EU-Norm)<br>Diese Relais werden \u00fcber die Shelly Cloud eingebunden.<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"391\" height=\"510\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-31.png\" alt=\"\" class=\"wp-image-1511\" style=\"width:196px;height:255px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-31.png 391w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-31-230x300.png 230w\" sizes=\"auto, (max-width: 391px) 100vw, 391px\" \/><figcaption class=\"wp-element-caption\">2PM Pro<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"451\" height=\"512\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-32.png\" alt=\"\" class=\"wp-image-1512\" style=\"width:226px;height:256px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-32.png 451w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-32-264x300.png 264w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><figcaption class=\"wp-element-caption\">4PM Pro<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"372\" height=\"287\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-33.png\" alt=\"\" class=\"wp-image-1513\" style=\"width:186px;height:144px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-33.png 372w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-33-300x231.png 300w\" sizes=\"auto, (max-width: 372px) 100vw, 372px\" \/><figcaption class=\"wp-element-caption\">1PM<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"207\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-34.png\" alt=\"\" class=\"wp-image-1514\" style=\"width:125px;height:104px\"\/><figcaption class=\"wp-element-caption\">1PM mini<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"409\" height=\"345\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-35.png\" alt=\"\" class=\"wp-image-1517\" style=\"width:205px;height:173px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-35.png 409w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-35-300x253.png 300w\" sizes=\"auto, (max-width: 409px) 100vw, 409px\" \/><figcaption class=\"wp-element-caption\">Plug S<\/figcaption><\/figure>\n\n\n\n<p><strong>\u00c4ltere W\u00e4rmepumpen, Einbindung \u00fcber Relais<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-medium\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"266\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-3-300x266.png\" alt=\"\" class=\"wp-image-1700\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-3-300x266.png 300w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-3.png 346w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Beispiel-Bild einer W\u00e4rmepumpe (Luft aussenaufgestellt)<\/figcaption><\/figure>\n\n\n\n<p>Folgende Schnittstellen werden unterst\u00fctzt:<br>&#8211; <strong>EVU-Sperreingang<\/strong> (1x Relais f\u00fcr Freigabe\/Sperrung)<br>&#8211; <strong>SG-Ready<\/strong> (2x Relais f\u00fcr 4 Betriebsmodi)<\/p>\n\n\n\n<figure class=\"wp-block-image size-thumbnail\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-2-150x150.png\" alt=\"\" class=\"wp-image-1699\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-2-150x150.png 150w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-2-100x100.png 100w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n\n\n\n<p><a href=\"https:\/\/www.waermepumpe.de\/normen-technik\/sg-ready\/\">SG Ready-Label | BWP | waermepumpe.de<\/a><\/p>\n\n\n\n<p><strong>Neuere W\u00e4rmepumpen, Einbindung \u00fcber Modbus TCP (LAN)<\/strong><br><br>Aktuell werden folgende Modelle \u00fcber Modbus-TCP unterst\u00fctzt:<br>&#8211; Alle <strong>Stiebel Eltron<\/strong> \u00fcber ISG (Internet Service Gateway)<br>&#8211; <strong>CTA<\/strong> OptiHeat Inverta Economy &amp; TWW (kein Gateway notwendig)<br>&#8211; Alle <strong>Hoval<\/strong>-Modelle \u00fcber HovalConnect Modbus Gateway<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"395\" height=\"395\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-36.png\" alt=\"\" class=\"wp-image-1518\" style=\"width:296px;height:296px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-36.png 395w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-36-300x300.png 300w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-36-150x150.png 150w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-36-100x100.png 100w\" sizes=\"auto, (max-width: 395px) 100vw, 395px\" \/><figcaption class=\"wp-element-caption\">Stiebel Eltron<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"455\" height=\"282\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-37.png\" alt=\"\" class=\"wp-image-1519\" style=\"width:228px;height:141px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-37.png 455w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-37-300x186.png 300w\" sizes=\"auto, (max-width: 455px) 100vw, 455px\" \/><figcaption class=\"wp-element-caption\">ISG<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"264\" height=\"506\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-38.png\" alt=\"\" class=\"wp-image-1520\" style=\"width:198px;height:380px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-38.png 264w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-38-157x300.png 157w\" sizes=\"auto, (max-width: 264px) 100vw, 264px\" \/><figcaption class=\"wp-element-caption\">CTA Inverta Economy<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-medium is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"232\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-4-300x232.png\" alt=\"\" class=\"wp-image-1701\" style=\"width:300px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-4-300x232.png 300w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2026\/10\/image-4.png 540w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><figcaption class=\"wp-element-caption\">Hoval Connect Gateway<\/figcaption><\/figure>\n\n\n\n<p><strong>Ladestationen f\u00fcr E-Fahrzeuge<\/strong> <strong>\u00fcber Modbus TCP (LAN)<\/strong><br>Folgende Modelle werden aktuell unterst\u00fctzt:<br>&#8211; Wallbe Eco (Auslaufmodell)<br>&#8211; Wallbe &amp; Weidm\u00fcller Pro (Auslaufmodell)<br>&#8211; ABB Terra AC (nicht empfohlen)<br>&#8211; Keba P30 (f\u00fcr EFH empfohlen)<br>&#8211; Webasto Next (f\u00fcr EFH empfohlen)<br>&#8211; Smart-me Pico (f\u00fcr MFH empfohlen)<br><\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"406\" height=\"334\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-39.png\" alt=\"\" class=\"wp-image-1522\" style=\"width:305px;height:251px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-39.png 406w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-39-300x247.png 300w\" sizes=\"auto, (max-width: 406px) 100vw, 406px\" \/><figcaption class=\"wp-element-caption\">Wallbe Eco<br><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"451\" height=\"440\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-40.png\" alt=\"\" class=\"wp-image-1523\" style=\"width:226px;height:220px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-40.png 451w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-40-300x293.png 300w\" sizes=\"auto, (max-width: 451px) 100vw, 451px\" \/><figcaption class=\"wp-element-caption\">Wallbe Pro<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"597\" height=\"535\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-41.png\" alt=\"\" class=\"wp-image-1524\" style=\"width:299px;height:268px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-41.png 597w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-41-300x269.png 300w\" sizes=\"auto, (max-width: 597px) 100vw, 597px\" \/><figcaption class=\"wp-element-caption\">Weidm\u00fcller Pro<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"276\" height=\"407\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-42.png\" alt=\"\" class=\"wp-image-1525\" style=\"width:138px;height:204px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-42.png 276w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-42-203x300.png 203w\" sizes=\"auto, (max-width: 276px) 100vw, 276px\" \/><figcaption class=\"wp-element-caption\">ABB Terra AC<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"403\" height=\"461\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-43.png\" alt=\"\" class=\"wp-image-1526\" style=\"width:202px;height:231px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-43.png 403w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-43-262x300.png 262w\" sizes=\"auto, (max-width: 403px) 100vw, 403px\" \/><figcaption class=\"wp-element-caption\">Webasto Next<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"213\" height=\"354\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-44.png\" alt=\"\" class=\"wp-image-1527\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-44.png 213w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-44-181x300.png 181w\" sizes=\"auto, (max-width: 213px) 100vw, 213px\" \/><figcaption class=\"wp-element-caption\">Keba P30<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-1024x1024.png\" alt=\"\" class=\"wp-image-1528\" style=\"width:256px;height:256px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-1024x1024.png 1024w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-300x300.png 300w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-150x150.png 150w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-768x768.png 768w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-1536x1536.png 1536w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45-100x100.png 100w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-45.png 1800w\" sizes=\"auto, (max-width: 706px) 89vw, (max-width: 767px) 82vw, 740px\" \/><figcaption class=\"wp-element-caption\">Smart-me Pico<\/figcaption><\/figure>\n\n\n\n<p><strong>Wechselrichter und Batteriesysteme \u00fcber Modbus TCP (oder RTU)<\/strong><br>Im Prinzip werden alle Hersteller\/Modelle mit <strong>Sunspec<\/strong>*-Protokoll unterst\u00fctzt<br>* standardisiertes Kommunikationsprotokoll gem\u00e4ss <a href=\"http:\/\/sunspec.org\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/sunspec.org<\/a><\/p>\n\n\n\n<p>Folgende Hersteller wurden getestet:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"242\" height=\"343\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-46.png\" alt=\"\" class=\"wp-image-1536\" style=\"width:182px;height:257px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-46.png 242w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-46-212x300.png 212w\" sizes=\"auto, (max-width: 242px) 100vw, 242px\" \/><figcaption class=\"wp-element-caption\">SolarEdge<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"770\" height=\"1024\" src=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-48-770x1024.png\" alt=\"\" class=\"wp-image-1538\" style=\"width:193px;height:256px\" srcset=\"https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-48-770x1024.png 770w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-48-225x300.png 225w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-48-768x1022.png 768w, https:\/\/smart-energy-engineering.ch\/wp-content\/uploads\/2025\/10\/image-48.png 835w\" sizes=\"auto, (max-width: 706px) 89vw, (max-width: 767px) 82vw, 740px\" \/><figcaption class=\"wp-element-caption\">Fronius Symo<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Der Eigenverbrauchsmanager unterst\u00fctzt aktuell folgende Ger\u00e4te ABB Stromz\u00e4hler (mit MID Zulassung)&#8211; Baureihe B23\/24 Dreiphasen Ein-\/Zweirichtungsz\u00e4hler Modbus RTU oder M-Bus*, direktmessend oder Wandler*f\u00fcr die M-Bus-Variante ist ein M-Bus-TCP-Konverter notwendig Eltako Stromz\u00e4hler (mit MID Zulassung)&#8211; Baureihe DSZ14-(W)DRS Dreiphasen-Einrichtungsz\u00e4hler, direktmessend oder WandlerEs wird ein Eltako FAM14-Koppler und FBA14 ben\u00f6tigt. Shelly Stromz\u00e4hler&#8211; Shelly 3EM Dreiphasen-Zweirichtungsz\u00e4hler WLAN \u00fcber Wandler&#8211; Shelly &hellip; <\/p>\n<p class=\"link-more\"><a href=\"https:\/\/smart-energy-engineering.ch\/?page_id=1469\" class=\"more-link\"><span class=\"screen-reader-text\">\u201eUnterst\u00fctzte Ger\u00e4te\u201c <\/span>weiterlesen<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1469","page","type-page","status-publish","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=\/wp\/v2\/pages\/1469","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1469"}],"version-history":[{"count":23,"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=\/wp\/v2\/pages\/1469\/revisions"}],"predecessor-version":[{"id":1706,"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=\/wp\/v2\/pages\/1469\/revisions\/1706"}],"wp:attachment":[{"href":"https:\/\/smart-energy-engineering.ch\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1469"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}